Troubleshooting 5-29
M M L 0 0
5.2.28. E2C1 STAPLER POS. ERROR
Figure 5-15. Error Code E2C1, E2C5 & E2CB
PRIMARY FACTOR; During the Stapler Unit movement, the Staple horizontal position cannot be detected.
PHENOMENON CAUSES & CHECK POINTS CORRECTIONS Maintenance
Ref + Page
1. This phenomenon
occurs because
the Stapler Unit
does not move
normally.
1. The drive system for the
Stapler Unit is faulty.
Check: Stapler Unit or its
environs.
2. Motor fault. Replace:
Stapler Movement Motor (M11) 3.5, 3-7
3. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN23 - M11
4. PCB fault. Replace: FS-108H/HBM P/K
3.5, 3-7
2. This phenomenon
occurs though the
Stapler Unit
operates.
1. The mounting of the
sensor is faulty.
Reset:
Stapler Movement HP PS (PS11)
3.4, 3-3
2. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN25 - PS11
3. Sensor fault. Replace:
Stapler Movement HP PS (PS11)
3.4, 3-3
4. PCB fault. Replace: FS-108H/HBM P/K 3.5, 3-7